- Welcome, Guest. Please Login or Register
Telcom Pro's - Switch Technicians unite!  
   
  HomeHelpSearchLoginRegister   
     
     
   
 
Page Index Toggle Pages: 1 Send Topic Print  
PRI B chnl remote busies or lockouts
Read 7047 times
boswald   Ex Member


   
     
 
PRI B chnl remote busies or lockouts
Dec 10th, 2004 at 11:22am
 
The Dms-100 and its PRI application,upon turnup with a vendor, had incurred lockouts or RMB's on the B chnls.
The fix for this problem was to set the DLC/module/port to INS from Auto Enable.
 
 
 
IP Logged    
 
     

Paul   Offline
Site Administrator
Switch Technician

*****
Posts: 472
Southern Maine


   
     
 
Re: PRI B chnl remote busies or lockouts
Reply #1 - Dec 13th, 2004 at 1:50pm
 
Bill,

This is concerning the Adtran 4303 only?  The Adtran 2820 mux's don't share this issue do they?
 
 
  WWW Paul 256433011082857 3636741
IP Logged    
 
     
Page Index Toggle Pages: 1 Send Topic Print  
Bookmarks
Google Digg del.icio.us Facebook reddit Twitter Linked in MySpace StumbleUpon Yahoo