loop start disconnect supervision
Jan 14th, 2014 at 9:02am
 
I have heard multiple discussion on this topic, but i have a fix that we use in the DMS-10, we take a 6x18 card and set the dipswitches for ground on the line card. and set the start for LPDS in OVLY cpk.  unfortuneately my company no longer has helmsman. was looking for the dipswitch settings on the card for start. and trying to remember if it his just gnd=n in lninv. any help would be appreaciated
 
 
 
IP Logged    
 
     

1palm   Offline
Senior Member
Switch Technician

*****
Posts: 251


   
     
 
Re: loop start disconnect supervision
Reply #1 - Jan 14th, 2014 at 12:17pm
 
Here's data for dms100...
Disclaimer: old notes, not sure what release(s) 6x18aa these notes apply to:

6x18aa      loop -----> 2
           grnd <-----      1
           lninv gnd set 'n' = 6x18 provisioned for loop start
           
6x18aa      loop <----      2
           grnd ----->      1
           lninv gnd set 'y' = 6x18 provisioned for ground start
           
 
 
 